YUEQING WINSTON ELECTRIC CO.,LTD.

Yueqing Winston Electric Co., Ltd Proximity sensor,switching power supply,voltage stabilizer,motor soft starter,frequency inverter,float switch,AC magnetic contactor, thermal overload relay, terminal

Manufacturer from China
Site Member
10 Years
Home / Products / Molded Case Circuit Breaker /

Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent

Contact Now
YUEQING WINSTON ELECTRIC CO.,LTD.
Province/State:zhejiang
Country/Region:china
Contact Person:MsTess Wong
Contact Now

Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent

Ask Latest Price
Video Channel
Brand Name :Winston/OEM
Model Number :WCM1
Certification :CE,ROSH
Place of Origin :China,Zhejiang
MOQ :1PCS
Price :USD10 to USD450/PCS
Payment Terms :T/T,L/C,Paypal,Online Payment,RMB/USD
Supply Ability :10000PCS/Month
Delivery Time :3-15days after get payment.
Packaging Details :Export standard carton box
Material :Plastic
Current :from 6A to 1600A
Poles :3,4
Frequency :50/60HZ
Rated operating voltage :400V or below
OEM :Yes
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent

WCM1 series moulded case circuit breaker is one of products developed and manufactured by adopting international advanced technology. It is supplied with rated insulating voltage 550 and 800V and used for circuit of AC 50/60Hz, rated operating voltage AC 400V (or below), rated operating current up to 1600A for infrequent changing over and starting of the motors.The products conforms to IEC60947-2 standard.

TECHNICAL PARAMETER

Main Technical Specification(table1)

Type

Rated
current (A)

Polenum-ber

Ratedinsui-atingvolt-age(V)

Rated
operat-ingvolt-age(V)

Arcing-
over
distance
(mm)

Ultimate
short
circuit
breaking
capacity
(KA)

Servies
short
circuit
breaking
capacity
(KA)

Operation
perform-
ance

Utiliza-tioncat-egory

Load

Unload

WCM1-63L

(6),10
16,20
25 ,32
40,50
63

3, 4

500V

400V

0

25

18

1500

8500

A

WCM1-63M

0

50

35

WCM1-100L

(10),16
20,25
32,40
50,63
80,100

800V

0(≤50)

35

22

WCM1-100M

0(≤50)

50

35

WCM1-100H

0(≤50)

85

50

1000

7000

WCM1-225L

100,125
160,180
200,225

≤50

35

22

WCM1-225M

≤50

50

35

WCM1-225H

≤50

85

50

1000

4000

WCM1-400L

225,250
315,350
400

≤50

50

35

WCM1-400M

≤100

65

42

WCM1-630L

400,500
630

≤100

50

35

WCM1-630M

≤100

65

42

WCM1-630H

≤100

100

65

WCM1-800M

630,700
800

3

≤100

75

50

WCM1-800H

≤100

100

65

WCM1-1250M

1000,1250

≤100

100

65

WCM1-1250H

≤100

125

75

WCM1-1600M

1600

≤100

150

80


Note: 6A without thermal protection
The N-pole of four-poles breaker is sited at the right side of the product has four types:
Type A: Without current trip-lease on N pole which making all the time, not closing and opening with the other three poles.
Type B: Without current trip-release on N pole which closing and opening with the other poles.
Type C: With current trip-release which closing and opening with the other three poles.
Type D: With current trip-release which making all the time not closing and opening with the other three poles.

Protection Characteristic
The thermodynamic release of a circuit breaker provides the feature of inverse time-delay, while the magnetic release is the instantaneous operation as shown on table 2(distribution circuit breaker) and table 3 (motor protection circuit breaker).


Table2

Rated current of release (A)

Thermodynamic release( ambient temperature ) land +40°C marine +45°C

Operating current of magnetic release (A)

1.05In(cold state) Inoperative time(h)

1.30In(heat state) Operative time(h)

10≤In≤63

≥ 1

< 1

10In±20%

63

≥ 2

< 2

100≤In≤800

≥ 2

< 2

5In±20% 10In±20%



Table3

Rated current

Thermodynamic release ( ambient temperature ) land +40°C marine +45°C

Operating current of magnetic release (A)

of release (A)

1.0In(cold state) non-trip time(h)

1.20In(heat state) trip time (h)

1.50In(heat state) trip time (h)

7.2In(cold state) trip time(h)

10 ≤ In ≤ 225

≥ 2

<2

≤ 4min

4s < Tp ≤ 10s

12In±20%

225 ≤ In ≤ 630

≤ 8min

6s < Tp ≤ 20s



Accessories of Circuit breaker
1 The external accessories of the breaker
Motor-driven operation device
1) Wiring diagram of type CDM electromagnetic operation device(fitting AM1-63,100,225) seethe following drawing (wiring diagram of the external accessories of the breaker in the dotted frame)

Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent



Code description: SB1SB2stand for push button.(provided by users themselves) Number "1" "2" "3" stand for number of wiring terminals.
Voltage rating: AC50Hz 230V 400V DC 220V
2) Wiring diagram of type CD motor-driven operation device (fitting AM1-400 630 800) seebelows (wiring diagram of the external accessories of the breaker in the dotted frame)

Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent




Code description: SB1SB2stand for push button. (provided by users themselves) "X" stands for line connection terminals
Voltage rating: AC50Hz 230V 400V DC 220V



Rotary handle operation device
The mechanism is used in moulded case circuit breaker to operate the draw-out panel. Powerdistribution panel and supply box outside the panel by turning the handle ,and to ensure thedoor of panel would not be openned when the breaker being on. The hand-drive mechanism can be equiped with two types of operation, one is "A" modelsquare handle , the other is "B" model round handle.

Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent



4.2 Release pattern and accessories code
Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent
SHT: Shunt release; UVR: Under-voltage release;AX: Auxiliary contact; AL: Alarm contact

Release patternand accessories code Name/Type WCM1-63,
100, 225
WCM1-400 WCM1-630 WCM1-800
200, 300 No accessories 200: magnetic release (only short circuit protection)300: thermal magnetic release(both overload and short circuit protection)
208, 308 Alarm contact Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent
210, 310 Shunt release Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent
220, 320 Auxiliary contact Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent
230, 330 Under-voltage release Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent
240, 340 Shunt release
Auxiliary contact
Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent
250, 350 Shunt release
Under-voltage release
Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent
260, 360 Two group of auxiliary contact Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent
270,370 Under-voltage release
Auxiliary contact
Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent
218, 318 Shunt release
Alarm contact
Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent
228, 328 Alarm contact Auxiliary contact Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent
238, 338 Under-voltage releaseAlarm contact Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent
248, 348 Shunt release, Alarm contact,Auxiliary contact Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent
268, 368 Two group of auxiliary contact,Alarm contact Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent
278, 378 Shunt release, Alarm contact, Under-voltage release Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent


According to user's demands, accessories could lead to direct wire outcoming or line wiringterminals could be added(please mark out in case of making order).

Under-voltage release
Wring diagram of the under-voltage module connected externally (the internal accessories inthe dotted frame)Ue: AC50Hz 230V, 400V

Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent



When the operation voltage is 35%~70% of the rated voltage, the under-voltage release shouldmake the breaker trip correctly.When the operation voltage is 85%~110% of the rated voltage, the under-voltage release shouldmake the breaker close.In case of the operation voltage less than 35% of the rated voltage, the under-voltage shouldprevent the breaker from closing.Note: Only the under-voltage release should be energized in advanced, the breaker could berecramped and turned-on, otherwise the breaker will be damaged.


Shunt release
Scheme of wiring(the internal accessories in the dotted frame)"K" is the slow motion switch normal-close contact connect the coil in series in the shunt release.It turns-on or turns-off voluntarily as soon as the breaker on or off.

Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent



Voltage rating: AC50Hz 230V or 400V, DC 110V 220VThe shunt release should make the breaker trip reliably when the operation voltage is 70%~110%of the rated control voltage.

Alarm contact
The position of the breaker in "off" or "on" Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent
The position of the breaker in "free trip" (alarm)
B11 and B12 switch from "close" to "open", statusof B11 and B14 switch from "open" to "close"


Auxiliary Contact
When the breaker is in"off" Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent For the breaker with frame current400A and above
Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent For the breaker with frame current225A and below
When the breaker is in"on" When the breaker is in "off", the contacts switch from "close" to "open".When the breaker is in "off",the contacts switch from "open"to close"

Inquiry Cart 0