47 - 63Hz Single Output DIN Rail Switching Power Supply DR - 45W Load Stability
Summary
Technique parameter:
Model | DR-45-5 | DR-45-12 | DR-45-15 | DR-45-24 |
DC output voltage current | 5V 0-5A | 12V 0-3.5A | 15V 0-2.8A | 24V 0-2A |
Wave and noise | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p |
Inlet stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stablity | ±1% | ±0.5% | ±0.5% | ±0.5% |
Efficiency | 72% | 77% | 77% | 80% |
Adjustable range for DC voltage | ±10% | ±10% | ±10% | ±10% |
input voltage range | 85-264VAC 120-370VDC 47-63Hz | |||
Inpact current | Cold start current 56A/230VAC 28A/115VAC | |||
Overload proctection | 105%-150% cut off the output, automatic recovery | |||
Over-voltage protection | 115%-135% shut down O/P voltage, re-power on to recover | |||
Setup rise hold up time | 800ms, 60ms, 50ms/230vac at full load | |||
Withstand voltage | I/P-O/P: 1.5KV I/P-FG:1.5KV O/P-FG:0.5KV 1minute | |||
Isolation resistance | I/P-O/P I/P-FG O/P-FG: 500VDC/100MΩ | |||
Working temperature | -10℃~+50℃ | |||
Overall dimension | 78*93*56mm | |||
Weight | 0.27kg | |||
Packing | 43*32*21.5cm/45PCS/12.5kg |
Product Picture
Dimensions
The installation of power supply
Please use the appropriate screw, fixed the power supply to the right environment, screw length should be less than 6 mm, not to the circuit boards, conductive danger to avoid touching the internal components. Power supply working space should have ventilation channel or exhaust equipment;In order to ensure the safety of using and reduce interference, please ensure that the grounding line should be good grounding, grounding line is greater than the AWGI#. After the installation, please measure the shell with the input, the output, insulation resistance in order to avoid electric shock.
The use of power supply
1 . Use the power of money make sure the input voltage specification (110 v / 220 v / 380 v) and going to install and use the power of the input voltage of nominal value.Domestic use products, the main input 220 VAC, so have a selection of 110 V / 220 V, under normal circumstances, the selector switch in the 220 VAC, please pay more attention to customers to use.
2 . In strict accordance with the drawings standard connection, check whether the input and output wires is correct before electricity, so as not to damage the user equipment.
About us
PS: If you can't find the exact type of your product.Please don't rush to go away.Contact me and your questions will be replied ASAP.Thank you for your time.