Add to Cart
0.6KG Single Output Power Supply S-120-24 12 Voltage 30A Cold Start Current
Summary
Technique parameter:
Model | S-120-12 | S-120-15 | S-120-18 | S-120-24 | S-120-36 | S-120-48 |
DC output voltage current | 12V 0-10A | 15V 0-8A | 18V 0-6.7A | 24V 0-5A | 36V 0-3.3A | 48V 0-2.5A |
Wave and noise | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
Inlet stability | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% | ±0.2% |
Load stablity | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% | ±0.2% |
Efficiency | 81% | 82% | 84% | 84% | 84% | 84% |
Adjustable range for DC voltage | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% |
input voltage range | 90-132VAC/180-264VDC by switch 254-370VDC 47-63Hz | |||||
Inpact current | Cold start current 60A/230VAC 30A/115VAC | |||||
Overload proctection | 105%-150% cut off the output, automatic recovery | |||||
Over-voltage protection | 115%-135% shut down O/P voltage, re-power on to recover | |||||
Setup rise hold up time | 200ms, 50ms, 20ms/230vac at full load | |||||
Withstand voltage | I/P-O/P: 1.5KV I/P-FG:1.5KV O/P-FG:0.5KV 1minute | |||||
Isolation resistance | I/P-O/P I/P-FG O/P-FG: 500VDC/100MΩ | |||||
Working temperature | -10℃~+50℃ | |||||
Overall dimension | 199*98*38mm | |||||
Weight | 0.6kg | |||||
Packing | 43*32.5*24cm/30PCS/18kg |
Product Picture
Dimensions
The use of power supply
1 . Use the power of money make sure the input voltage specification (110 v / 220 v / 380 v) and going to install and use the power of the input voltage of nominal value.Domestic use products, the main input 220 VAC, so have a selection of 110 V / 220 V, under normal circumstances, the selector switch in the 220 VAC, please pay more attention to customers to use.
2 . In strict accordance with the drawings standard connection, check whether the input and output wires is correct before electricity, so as not to damage the user equipment.
The installation of power supply
Please use the appropriate screw, fixed the power supply to the right environment, screw length should be less than 6 mm, not to the circuit boards, conductive danger to avoid touching the internal components. Power supply working space should have ventilation channel or exhaust equipment;In order to ensure the safety of using and reduce interference, please ensure that the grounding line should be good grounding, grounding line is greater than the AWGI#. After the installation, please measure the shell with the input, the output, insulation resistance in order to avoid electric shock.
About us
PS: If you can't find the exact type of your product.Please don't rush to go away.Contact me and your questions will be replied ASAP.Thank you for your time.